Tuesday, 3 January 2017

A Review on SVD Based Watermarking Schemes

Vol. 2  Issue 1
Year:2014
Issue:Nov-Jan
Title:A Review on SVD Based Watermarking Schemes
Author Name:Samiksha Soni and Dr. Manisha Sharma
Synopsis:
SVD transformation has gained a wide popularity in the field of digital watermarking due to its characteristics. In this paper, the detailed analysis of SVD based watermarking algorithms are presented. The authors discuss in detail about the unique features of SVD transformation and working principles of the typical SVD based image watermarking algorithms that also elaborate the advantages and disadvantages of each.

A Novel Open End Slot Antenna for Ultra Wide Band Application

Vol. 2  Issue 1
Year:2014
Issue:Nov-Jan
Title:A Novel Open End Slot Antenna for Ultra Wide Band Application
Author Name:M.Sasikala and M.Duraisamy 
Synopsis:
A novel open end slot antenna for UWB application is proposed in this paper. It occupies a compact size of 2 23.5×23.5mm2 . Multiple resonances are generated by using an asymmetrical rectangular patch with the L-shaped open-slot structure. The proposed antenna provides wide bandwidth from 3.1 GHz to 11.02.6 GHz with -10 dB return loss.

Fractional Order PI Controller Technique for a Nonlinear Spherical Tank System

Vol. 2  Issue 1
Year:2014
Issue:Nov-Jan
Title:Fractional Order PI Controller Technique for a Nonlinear Spherical Tank System
Author Name:Marshiana.D and Thirusakthimurugan.P
Synopsis:
Fractional Order PI Controller Technique (FOPIC) offers success due to emerging of effective methods in differentiation and integration of the no integer order equation. In this research, the controller design using FOPIC is determined for a nonlinear system. The nonlinear system is taken up for the study is a spherical tank which is approximated to a first order system. Simulation is made by the MATLAB software.

Artificial Intelligent Control Of Induction Motor Drives

Vol. 2  Issue 1
Year:2014
Issue:Nov-Jan
Title:Artificial Intelligent Control Of Induction Motor Drives
Author Name:P. M. Menghal and Dr. A. Jaya Laxmi
Synopsis:
Induction Motors have many applications in the industries, because of the low maintenance and robustness. The speed control of induction motor is more important to achieve maximum torque and efficiency. The rapid development of power electronic devices and converter technologies in the past few decades, has made possible efficient speed control by varying the supply frequency and voltage, giving rise to various forms of adjustable-speed Induction Motor drives. In about the same period, there were also advances in control methods and Artificial Intelligence (AI) techniques, including expert system, fuzzy logic, neural networks and genetic algorithm. Researchers soon realized that the performance of induction motor drives can be enhanced by adopting Artificial Intelligent based methods. This paper presents an integrated environment for speed control of Induction Motor (IM) using artificial intelligent controller. The integrated environment allows users to compare simulation results between classical and artificial intelligent controllers. The fuzzy logic controller and artificial neural network controllers are also introduced to the system for keeping the motor speed to be constant when the load varies. The performance of fuzzy logic and artificial neural network based controllers is compared with that of the conventional proportional integral controller. The performance of the Induction motor drive has been analyzed for constant and variable loads.

Fault Detection & Diagnosis of Induction Machine with On-Line Parameter Programming Facility

Vol. 2  Issue 1
Year:2014
Issue:Nov-Jan
Title:Fault Detection & Diagnosis of Induction Machine with On-Line Parameter Programming Facility
Author Name:Sheikh Rafik Manihar Ahmed
Synopsis:
All instrumentation systems pertaining to industrial process controls as well as domestic application involves automatic fault finding facility. This facility detects the faulty condition of the system and draws the operator's attention towards it and enables to take suitable remedial actions to ensure proper operations of the system. The main purpose of all FDI methods is to monitor the system operations and in case of faults, accommodate the source of faults, so that timely corrective actions are taken. Fault Detection simply involves a decision, based on the monitoring data as to whether there is a fault or the system is running normally. Fault Isolation is then executed to identify the type and location of a fault after the fault detection has triggered an alarm so that corrective actions can be made. These two steps are known as Fault Detection and Isolation (FDI). Fault diagnosis is referred to as the combination of fault detection, identification and isolation. It is one such method of Annunciation in which the activation of visual or mechanical variable takes place when a removed switch or device has been activated as a result of fault in certain systems and an audio alarm may also be associated with annunciations. This FDI system is defined and the existing technique is to detect & isolate the fault with online parameter programming facility. The main advantage of the proposed approach of Control System based fault detection and isolation is its low cost. Low cost in terms of components used makes affordable in terms of easy handling and maintenance and various sensors can be used to give different types of input signals to circuit. An additional advantage is that the real time system still works when the host crashes, the matter that increases the reliability of the system & Data-logging facility can also be provided. A data-logger captures any measurement values which can be represented by a voltage. Nowadays, sensors and transducers are available for, practically, any physical quantity. The function of data-logger is to capture and store a specified number of sensor measurement values at predefined intervals and transfer the data, including date and time to a PC in the form of file.

Saturday, 5 July 2014

GA Based PID Control of Magnetic Levitation System

Vol.1  No.4

Year : 2013

Issue : Aug-Oct

Title : GA Based PID Control of Magnetic Levitation System

Author Name : S. KISHORE, D. VASANTHI

Synopsis :

The Magnetic levitation system serves as a simple model of devices, which are becoming popular in recent years. Magnetic Levitation System is a nonlinear, unstable system that can be applied in many application area such as in magnetic bearings, high speed trains, vibration isolation tables in semiconductor manufacturing, levitation of wind power generation, levitation of molten metal in induction furnaces, position tracking and levitation of metal slabs during manufacturing. The Magnetic levitation system can be categorized as a repulsive system and this system is based on the source of levitate forces. Since it is highly nonlinear and unstable system, it is very challenging in order to construct the high performance controllers to regulate the position of the levitation ball. This work involves the design of PID controller, Optimized PID controller. The real time implementation on the magnetic levitation kit has been carried out.In the above work, we acquired a high precision control to levitate a steel ball in the desired position.



For more details:

Fuzzy Logic Controller-An Advanced & Efficient Technique for Controlling Drives

Vol.1  No.4

Year : 2013

Issue : Aug-Oct

Title : Fuzzy Logic Controller-An Advanced & Efficient Technique for Controlling Drives

Author Name : R. SUMAN

Synopsis :

The basic idea is to design a fuzzy logic hysteresis comparator-based direct torque control scheme of an induction motor under varying dynamic conditions[1]. The major problem that is usually associated with DTC drive is the high torque ripple. To overcome this problem a torque hysteresis band with variable amplitude is proposed based on fuzzy logic[4]. The fuzzy logic controller is used to adjust the bandwidth of the torque hysteresis controller in order to reduce the torque and flux ripples and, to improve motor dynamic response[3],[4]. Based on the slopes of motor-estimated torque and stator current, an FLC is designed to select the optimum bandwidth of the torque hysteresis controller. In order to test the performance of the proposed FLC-based DTC scheme for IM drive, a complete simulation model is developed using MATLAB/Simulink.



For more details: